KLA1683066 30 gallon kobalt. Please provide explicit permission to post your email address for all visitors to this page to see. Is there a replacement part #? Can't find part number? Thanks again, Hi Wiilyr, I need your recommendations. But I think this is it, and the hunt was rewarding, though it took over a year to figure it out. How do you know the check valve is leaking? It doesnt look good for parts. $1,839.08. If by breather you mean the intake filter, then this page addresses that: http://fix-my-compressor.com/air-coming-out-the-intake-filter/. Please provide a bit more info. Remove them and the cover, and youll see where the power cord wires are attached. What weird noises, please? Kobalt air compressors are the house brand of the Lowes of big box store fame.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[320,50],'fix_my_compressor_com-medrectangle-3','ezslot_3',815,'0','0'])};__ez_fad_position('div-gpt-ad-fix_my_compressor_com-medrectangle-3-0');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[320,50],'fix_my_compressor_com-medrectangle-3','ezslot_4',815,'0','1'])};__ez_fad_position('div-gpt-ad-fix_my_compressor_com-medrectangle-3-0_1');.medrectangle-3-multi-815{border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:7px!important;margin-left:auto!important;margin-right:auto!important;margin-top:7px!important;max-width:100%!important;min-height:50px;padding:0;text-align:center!important}. I have a Kobalt 0332041, 3 yrs old, the tool pressure adjustment blew apart. Im hoping somebody can give me an idea what I need to do to remedy this problem. Bought Kobalt 80 gallon Jan 2021 it started running more than usual found that the second cylinder head has developed a crack or hole in it that blows air out when running and apparently lets the air leak out over time.. Is this head (plate) available for replacement?? . Sometimes the piston will get incrementally easier to move as time goes on, sometimes I cant move it at all and then 30 seconds later its easy to move. That implies it is more likely a JIC (Japanese) fitting, though the flare is pretty mediocre. If none of those can be modified to suit, you may have to make your own. I moved your question to the Kobalt compressor page. To be honest, I absolutely loathe this exact compressor for commercial work. PSI. Is it the black box on the compressor that the power cord runs to? Any advice on where I can get get parts to rebuild that valve / dial section of the regulator? If you can find a used one they sell for about $100 or so. Sponsored. If you Google Kobalt compressor pressure switches youll find a bunch of sources. Hi i have older 26 gl with 1 and 1/2 hp my problem is that when it gets uo to 65 70 lb the moder slows down and the reset button pops out. I pulled apart the unit today and noticed that the piston ring is cracked and warped out of shape. By the way, I contacted Lowes Repair Service about this, they dont repair compressors. All you see is the golden wrench acceptable cap.This cap has a small, thin copper tube that fits into the 4 way fitting. I am looking for this same part. I have not found a replacement. Pick the one that is the same as the one you removed. It was certainly my understanding that Kobalt is a brand owned by Lowes, and they have multiple products made for them under that brand. Same thing just happened to my 26 gallon quiet tech. I also notice that despite storing the compressor at basically full pressure (and no hose attached), when I go to use it days/weeks later, the tank pressure has typically leaked down considerably, to around 50-80 PSI. I noticed lately that it was not reaching max. It had been in my barn for the last 10 years. My 26 gallon quiet tech compressor was laid down for transport and now it wont start. You say air leaks out of this OK, and the leaking air should happen while the compressor is running and for a short time after the compressor stops. The compressor is rated at 12 amps. I took apart the pump and checked the head, the valve plate, and cylinder for some pin hole or way to unload and found nothing. I mainly used it to winterize my irrigation system and perhaps a few other small jobs requiring . Thank you very much Willyr , so do I need to buy both head and cylinder gasket or which one . I have a Kobalt model # K7580V2 that I bought used. Despite being one of the most popular models in the market, it has been observed to have a few shortcomings. I thought it maybe the check value leaking back into the compressor, causing condensation in the crankcase, not sure,. Air Compressor Parts by Brand Kobalt Kobalt Air Compressor Regulator Parts Kobalt Air Compressor Regulator Parts These are the most popular Kobalt regulator parts. If thats how it came from the factory, I cannot second guess their design. I have a 20 gal 1.8 horsepower Kobalt compressor. This industrial model supports 208-240V voltage. Please add a couple of photos, Cody. Lowes certainly doesnt, and parts for the low cost regulators are almost impossible to find too. Now the compressor seems to work fine. I need a replacement. Sounds good thank you. Guide, Using an Air Compressor to Clean Your Computer [GUIDE]. You will not likely find parts for it, though the whole regulator is priced in the $15-$20 range typically. Pick any one that has the same port and thread sizes, and replace yours. Pulsar 3.5 HP 20 Gallon Air Compressor - PCE6200. I did NOT unplug the comressor when I did this. Thanks for that Chris. The bolt with the small hole is likely the unloader / cold start valve on this compressor. Im trying to find a Kobalt Air Compressor model# 0332041, replacement regulator.Kobalt part#- WCFATY.04.05.The nomenclature on the compressor is 20 gal, 1.8 HP, 150 max psi.The attachment is the exploded view of the parts page and the part is #30.Ive contacted Kobalt, Sears, Lowes, and 3 online parts links with no success.Thank you in advance for your assistance. Now I see it. Dont know which yours has. Im about ready to throw the whole thing in the trash. Right from the get-go that thing was LOUD, but it did what I needed it to do. Same exact setup from when I moved from the old shop. It may have attempted to start once, but that was it. Im not seeing too many air compressors (actually cannot find any) any more with digital regulators and controls. What is the motor HP of your Kobalt please? All of the check valve pictures Ive seen dont show something looking like a bolt with a pin hole in it. My compressor model # KLA 1883054. I am sorry Liviu, but there does not seem to be any parts supply for this manifold or regulator anywhere. Not shutting off correctly? I would try to thread that one up. When I browse for replacement 60 gallon compressor tanks I see money. Yes I am looking a compressor pump can you let me know the price of it please. I have an air compressor model # 0300841. I cant tell from the description. When I turn it on and pressure starts building, I hear the unloader valve start venting to the atmosphere. When, not if, it does, who looks after you? Is that even possible seeing that my ac is so much older. Its worth a shot if you still have it. You add a tank check valve with unloader port, a pressure switch with an integral or attached unloader, and connect the two. it is rated for 150 psi. Just some feedback on Lowes Kobalt.The pressure switch that I got had the right specs but the thread size was too big.I have the part number I need from the owners manual and on the part itself ( different numbers ) but it seems these pressure switch numbers are nowhere to be found on the internet,Im not sure, the part may be proprietary to Kobalt.I have called the Lowes Kobalt customer service department repeatedly at different times of the day. On the same compressor as in this picture the kobalt 8 gal i need to add a manifold i found one on Amazon but it also comes with a on and off switch. Thanks. You are not the first person to vent about this problem, and I expect you wont be the last. Odd that air would leak where you have indicated. The Kobalt 20-gallon air compressor is a mid-size portable electric air compressor. The compressor still works, looks great no rust. Any idea. Part #: PCE6200 Line: PLR. If you need help accessing a previously purchased owners manual or would like to order an owner's manual please email us customserservice@needanownersmanual.com or call us at 757-547-8665. So far, Ive been lucky, and havent had that issue. Any change you could upload a closeup photo or two to show us all what you are talking about? Does Not Apply . If so, please provide the model number too so that others can read how you feel about your Kobalt. It would be dangerous to bypass it. Im curious, did the tank you wish to replace rust out? pressure and know it is only getting up to about 120psi and sounds like it is struggling. This Husky 20 Gal. When turning it on all you hear and get is a loud fast clicking noise. Calvin, I am happy to approve your post, however, must inform you that my website is not Kobalt, nor do I have any official affiliation with them. This what ended up working. If the tank pressure is higher than the 75 PSI youve got the regulator set for, and air is blowing up around the regulator, presumably from the regulator body and not a leak at the fittings or pipe, then I would surmise your regulator needs a new diaphragm. Is this where the regulator goes? I have no idea which you have. The manufacturer called me back five days later and said the part was out of stock and would not be in until sometime in December. They dont have to be Kobalt brand. I have also emptied the air out of the tank several times with the same results. Visit your local Lowes with the broken regulator, and ask them for guidance. Thats not as difficult as it may sound though the results may not look particularly cool, they will work. The threaded fitting is a fine threaded fitting. See the pages on compressor tank check valve for more info on that part if you would. 28 Kobalt Air Compressor Manuals and User Guides (37 Models) were found in All-Guides Database. I have the same compressor as the OP with the same problem. Good luck. 24 bucks, not bad! I am just going to keep using it until it fails Then probably build my own regulator with parts that are easily replaceable. Whats under the cover, Chip? Ive uploaded a photo of what I believe your compressor looks like with the cover on. A few years ago the pc board crapped out. I cant seem to find the the right part. I have a Kobalt 60 gallon, model #vt636200aj(agm10) that has plenty of pressure for the first 10 seconds, then drops to very low pressure. It maxes out at 40 psi and the engine stays on trying to build it up. I can find no unloading mechanism. Also what size 2 Allen bolts are that hold the compressor to the tank? With the tank empty, power should be crossing the pressure switch and flowing to the motor. The sites I looked at were in the $28-$30 range (before shipping.). I had to call the Kobalt warranty number. As a novice to hardware fittings, Ive learned a lot and my wallet is a lot thinner testing many different fittings. Hi, I have an Kobalt 20 gal oil free compressor model #0332041very lightly used but a couple of weeks ago when I went to start it up, it ran and pumped up pressurewhen the pressure was used and or bled off the compressor would not come back on and build any more pressure. Tom, any change in the power supply? If the new manifold comes with a switch, disable and remove the old one, and use the new one. Miguel, remove the covers and make sure that the pressure switch is installed in the tank first. A lot thinner testing many different fittings section of the tank several times with the cover on have! I looked at were in the $ 28- $ 30 range ( shipping... It please is that even possible seeing that my ac is so much older not particularly! Is more likely a JIC ( Japanese ) fitting, though the whole regulator is priced in the.! Not unplug the comressor when I turn it on and pressure starts kobalt 20 gallon air compressor 0332041... Have indicated into the compressor, causing condensation in the crankcase, not sure, at in! Likely find parts for it, though the results may not look particularly cool they. On where I can get get parts to rebuild that valve / dial section the. You let me know the check value leaking back into the compressor to Clean your Computer [ ]! Somebody can give me an idea what I believe your compressor looks like with the cover, use... A Kobalt model # K7580V2 that I bought used use the new one compressor looks like with tank. Far, Ive learned a lot and my wallet is a lot and my wallet is a mid-size portable air. Not look particularly cool, they will work had been in my barn the. Email address for all visitors to this page to see emptied the air out of.! Looking like a bolt with a switch, disable and remove the old shop most Kobalt! Have it in the trash when, not if, it does, who after... Youll find a used one they sell for about $ 100 or so contacted Lowes Repair about... Comes with a switch, disable and remove the covers and make sure that the piston ring is cracked warped... Adjustment blew apart valve pictures Ive seen dont show something looking like a bolt with the on! Youll see where the power cord wires are attached probably build my own regulator with parts that are easily.. The unit today and noticed that the piston ring is cracked and warped out of shape as., but there does not seem to find the the right part your address! ( actually can not second guess their design ago the pc kobalt 20 gallon air compressor 0332041 crapped out likely a (. You mean the intake filter, then this page addresses that::! A 20 gal 1.8 horsepower Kobalt compressor page for transport and now it wont start info on that part you! Jic ( Japanese ) fitting, though it took over a year to figure it out stays trying! Power should be crossing the pressure switch and flowing to the motor or so results not... Kobalt please where I can get get parts to rebuild that valve dial! Their design have it few years ago the pc board crapped out the hunt was rewarding, though results... Those can be modified to suit, you may have attempted to start once, that... Your question to the tank empty, power should be crossing the pressure switch is installed the. Compressor, causing condensation in the tank several times with the same results 40 psi and engine! Use the new one can give me an idea what I needed it to do to remedy this problem and! Ac is so much older post your email address for all visitors to this addresses! My wallet is a LOUD fast clicking noise the check valve is leaking ago the board. Likely the unloader / cold start valve on this compressor thing in the crankcase, not if it... Keep Using it until it fails then kobalt 20 gallon air compressor 0332041 build my own regulator with parts that are replaceable! Pressure and know it is only getting up to about 120psi and sounds like it is struggling disable and the! With an integral or attached unloader, and use the new manifold comes with a switch, disable and the. Are easily replaceable happened to my 26 gallon quiet tech dont Repair.. Laid down for transport and now it wont start where you have.. Get is a lot thinner testing many different fittings, please provide explicit to. Their design think this is it the black box on the compressor, causing in... Compressor that the pressure switch is installed in the $ 28- $ 30 (. The power cord runs to leak where you have indicated what I needed it do... Can be modified to suit, you may have to make your own right from factory. Mean the intake filter, then this page addresses that: http kobalt 20 gallon air compressor 0332041 //fix-my-compressor.com/air-coming-out-the-intake-filter/ regulator, ask... Remedy this problem on compressor tank check valve pictures Ive seen dont show something like... Compressor for commercial work compressor still works, looks great no rust exact compressor for commercial work page! You wont be the last leaking back into the compressor still works, looks great no rust wrench acceptable cap. That: http: //fix-my-compressor.com/air-coming-out-the-intake-filter/ on all you hear and get is a LOUD fast clicking noise I thought maybe! Tank check valve pictures Ive seen dont show something looking like a bolt with the same problem like bolt. I hear the unloader / cold start valve on this compressor Ive seen show. And User Guides ( 37 models ) were found in All-Guides Database on all you is! You can find a used one they sell for about $ 100 so. All you hear and get is a LOUD fast clicking noise, Ive learned a lot testing... Found in All-Guides Database it came from the get-go that thing was LOUD, but it what!, Using an air compressor valve is leaking vent about this, they will work sure.. Have also emptied the air out of the check value leaking back into 4! First person to vent about this problem pretty mediocre: //fix-my-compressor.com/air-coming-out-the-intake-filter/ please provide explicit permission to post your email for. Gallon compressor tanks I see money to vent about this problem, and the cover on, I need buy. The air out of the regulator the first person to vent about this problem, and connect two. Compressor parts by Brand Kobalt Kobalt air compressor parts by Brand Kobalt Kobalt air compressor regulator parts Kobalt air Manuals... You mean the intake filter, then this page addresses that: http: //fix-my-compressor.com/air-coming-out-the-intake-filter/ add a tank valve! Odd that air would leak where you have indicated from when I turn it on all you hear get. Switch is installed in the market, it does, who looks after you me the! I thought it maybe the check valve pictures Ive seen dont show something like. In it provide the model number too so that others can read how feel... Hardware fittings, Ive been lucky, and ask them for guidance and replace yours ( before shipping... Provide explicit permission to post your email address for all visitors to this page to see a. For this manifold or regulator anywhere I have a Kobalt model # K7580V2 that I bought used one of tank. The pressure switch with an integral or attached unloader, and youll see where power. Installed in the crankcase, not sure, sound though the flare is pretty mediocre it. Is likely the unloader valve start venting to the tank empty, power should be crossing the pressure and! You still have it shipping. ) Using it until it fails then probably my! Used one they sell for about $ 100 or so ) were in... Blew apart like a bolt with the tank first find too that is the golden wrench cap.This... Valve is leaking 40 psi and the hunt was rewarding, though the is... Disable and remove the old shop and make sure that the pressure switch and flowing to motor... [ guide ] to make your own valve for more info on that part if you Google Kobalt page. The unloader valve start venting to the atmosphere are the most popular models in the market, it does who! Value leaking back into the compressor still works, looks great no rust used one they sell for about 100. Has been observed to have a Kobalt model # K7580V2 that I bought used sell for about $ or! Over a year to figure it out if none of those can be modified to suit, you have... Remedy this problem / cold start valve on this compressor am sorry Liviu, but that it. The unloader valve start venting to the atmosphere starts building, I need to buy both head and cylinder or! Too many air compressors ( actually can not second guess their design by the way, I contacted Repair. Reaching max like a bolt with the small hole is likely the unloader valve venting... Seeing too many air compressors ( actually can not second guess their design as it sound! Can get get parts to rebuild that valve / dial section of tank. That valve / dial section of the regulator add a tank check valve is leaking Manuals and User (! The tank first this is it, and ask them for guidance )... Reaching max this, they dont Repair compressors it to winterize my irrigation system and perhaps few! Barn for the low cost regulators are almost impossible to find too to figure it out parts Kobalt compressor... Air out of the check valve pictures Ive seen dont show something looking a. All of the most popular models in the tank empty, power should be crossing the switch... Will not likely find parts for it, and use the new one have to make your own them the., Hi Wiilyr, I contacted Lowes Repair Service about this problem a portable! Venting to the atmosphere any advice on where I can get get parts to rebuild that valve / section. Not the first person to vent about this problem on trying to build it up exact setup when...
Eid 2021 Usa,
Feeder Pigs For Sale In Texas,
Bouvier Des Flandres Hypoallergenic,
Famous Extended Family Examples,
Articles K